{"product_id":"olympus-bf-uc180f-evis-exera-ii-ebus-ultrasonic-bronchofibervideoscope","title":"Olympus BF-UC180F EVIS EXERA II EBUS Ultrasonic Bronchofibervideoscope","description":"\u003ch2 data-section-id=\"1cielx\" data-start=\"1430\" data-end=\"1507\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"1433\" data-end=\"1507\"\u003eOlympus BF-UC180F EVIS EXERA II EBUS Ultrasonic Bronchofibervideoscope\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"1509\" data-end=\"1993\"\u003eThe \u003cstrong data-start=\"1513\" data-end=\"1534\"\u003eOlympus BF-UC180F\u003c\/strong\u003e is an advanced \u003cstrong data-start=\"1550\" data-end=\"1619\"\u003eEBUS (Endobronchial Ultrasound) ultrasonic bronchofibervideoscope\u003c\/strong\u003e designed to support highly accurate pulmonary diagnostics and minimally invasive transbronchial needle aspiration procedures. As part of the trusted \u003cstrong data-start=\"1769\" data-end=\"1803\"\u003eOlympus EVIS EXERA II platform\u003c\/strong\u003e, the BF-UC180F combines high-quality endoscopic visualization with real-time ultrasound imaging for enhanced lymph node assessment and tissue sampling. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1995\" data-end=\"2370\"\u003eEngineered specifically for \u003cstrong data-start=\"2023\" data-end=\"2047\"\u003eEBUS-TBNA procedures\u003c\/strong\u003e, the BF-UC180F features a uniquely designed distal tip that improves access to difficult-to-reach nodal stations such as 4L and 10R. Its real-time ultrasound guidance and improved maneuverability help clinicians achieve accurate tissue acquisition and reliable diagnostic performance. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 data-section-id=\"1pi78xj\" data-start=\"2377\" data-end=\"2407\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"2380\" data-end=\"2407\"\u003eKey Features \u0026amp; Benefits\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong data-start=\"2411\" data-end=\"2456\"\u003eReal-Time Endobronchial Ultrasound (EBUS)\u003c\/strong\u003e\u003cbr data-start=\"2456\" data-end=\"2459\"\u003eProvides direct ultrasound visualization for accurate needle placement and lymph node sampling during EBUS-TBNA procedures. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong data-start=\"2626\" data-end=\"2657\"\u003eOptimized Distal Tip Design\u003c\/strong\u003e\u003cbr data-start=\"2657\" data-end=\"2660\"\u003eShort rigid distal tip enhances angulation and access to challenging nodal stations for improved procedural efficiency. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong data-start=\"2823\" data-end=\"2861\"\u003eHigh-Resolution Ultrasound Imaging\u003c\/strong\u003e\u003cbr data-start=\"2861\" data-end=\"2864\"\u003eSupports precise visualization of mediastinal and hilar lymph nodes during pulmonary staging procedures. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong data-start=\"3012\" data-end=\"3041\"\u003e2.2 mm Instrument Channel\u003c\/strong\u003e\u003cbr data-start=\"3041\" data-end=\"3044\"\u003eLarger working channel improves suction capability and allows smoother insertion of EBUS accessories and aspiration needles. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong data-start=\"3212\" data-end=\"3256\"\u003eAdvanced Pulmonary Diagnostic Capability\u003c\/strong\u003e\u003cbr data-start=\"3256\" data-end=\"3259\"\u003eDesigned for accurate staging and diagnosis of lung cancer and mediastinal disease. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong data-start=\"3386\" data-end=\"3429\"\u003eElectronic Curved Linear Array Scanning\u003c\/strong\u003e\u003cbr data-start=\"3429\" data-end=\"3432\"\u003eEnables real-time ultrasound-guided tissue acquisition with high precision. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong data-start=\"3551\" data-end=\"3580\"\u003eExcellent Maneuverability\u003c\/strong\u003e\u003cbr data-start=\"3580\" data-end=\"3583\"\u003eErgonomic insertion design supports smoother navigation through bronchial anatomy during complex procedures. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 data-section-id=\"id1bjs\" data-start=\"3738\" data-end=\"3769\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"3741\" data-end=\"3769\"\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong data-start=\"3773\" data-end=\"3783\"\u003eModel:\u003c\/strong\u003e BF-UC180F\u003c\/p\u003e\n\u003cp\u003e\u003cstrong data-start=\"3798\" data-end=\"3809\"\u003eSeries:\u003c\/strong\u003e Olympus EVIS EXERA II\u003c\/p\u003e\n\u003cp\u003e\u003cstrong data-start=\"3836\" data-end=\"3845\"\u003eType:\u003c\/strong\u003e Ultrasonic Bronchofibervideoscope (EBUS Scope)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong data-start=\"3897\" data-end=\"3913\"\u003eApplication:\u003c\/strong\u003e Endobronchial Ultrasound (EBUS-TBNA)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong data-start=\"3955\" data-end=\"3973\"\u003eField of View:\u003c\/strong\u003e 80° \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong data-start=\"4020\" data-end=\"4042\"\u003eDirection of View:\u003c\/strong\u003e 35° Forward Oblique \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong data-start=\"4107\" data-end=\"4126\"\u003eDepth of Field:\u003c\/strong\u003e 2–50 mm \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong data-start=\"4179\" data-end=\"4203\"\u003eDistal End Diameter:\u003c\/strong\u003e 6.9 mm \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong data-start=\"4255\" data-end=\"4283\"\u003eInsertion Tube Diameter:\u003c\/strong\u003e 6.2–6.3 mm \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong data-start=\"4339\" data-end=\"4358\"\u003eWorking Length:\u003c\/strong\u003e 600 mm \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong data-start=\"4410\" data-end=\"4442\"\u003eInstrument Channel Diameter:\u003c\/strong\u003e 2.2 mm \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong data-start=\"4494\" data-end=\"4515\"\u003eAngulation Range:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUp: 120°\u003c\/p\u003e\n\u003cp\u003eDown: 90° \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong data-start=\"4591\" data-end=\"4622\"\u003eUltrasound Scanning Method:\u003c\/strong\u003e Electronic Curved Linear Array \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong data-start=\"4698\" data-end=\"4716\"\u003eCompatibility:\u003c\/strong\u003e Olympus EU-ME1 \/ EU-ME2 ultrasound processors \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 data-section-id=\"k0zlak\" data-start=\"4811\" data-end=\"4830\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"4814\" data-end=\"4830\"\u003eApplications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003eEBUS-TBNA procedures\u003c\/p\u003e\n\u003cp\u003eLung cancer staging\u003c\/p\u003e\n\u003cp\u003eMediastinal lymph node evaluation\u003c\/p\u003e\n\u003cp\u003ePulmonary diagnostics\u003c\/p\u003e\n\u003cp\u003eReal-time ultrasound-guided tissue sampling\u003c\/p\u003e\n\u003cp\u003eBronchoscopic ultrasound procedures\u003c\/p\u003e\n\u003cp\u003eInterventional pulmonology\u003c\/p\u003e\n\u003ch2 data-section-id=\"tao074\" data-start=\"5259\" data-end=\"5295\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"5262\" data-end=\"5295\"\u003eWhy Choose Olympus BF-UC180F?\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"5297\" data-end=\"5720\"\u003eThe BF-UC180F is trusted by pulmonologists and thoracic specialists worldwide for its combination of \u003cstrong data-start=\"5398\" data-end=\"5518\"\u003ereal-time ultrasound imaging, precise needle guidance, enhanced maneuverability, and reliable diagnostic performance\u003c\/strong\u003e. Its optimized distal tip design and high-resolution EBUS capability make it a leading solution for advanced pulmonary staging and tissue acquisition procedures.\u003c\/p\u003e","brand":"Olympus Corporation","offers":[{"title":"Default Title","offer_id":53130655531119,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0708\/9002\/9167\/files\/Olympus_BF-UC180F_EBUS_ultrasonic_bronchofibervideoscope.png?v=1779296142","url":"https:\/\/eighteenflexendo.com\/products\/olympus-bf-uc180f-evis-exera-ii-ebus-ultrasonic-bronchofibervideoscope","provider":"Eighteen Flex Endo","version":"1.0","type":"link"}